• Precision Measurement Technologies
  • Technology Center for

Magnetostrictive Positioning

The contact-less registration of positions, driving movements etc. are a required method for procedure automation, so that re-registration can take place in the actual situation of the system. Often precision in the µm range are needed. The systems need to be robust, with little required maintenance and (of course) inexpensive. Several years ago a method was established, where ultrasonic delay time on a wire was used to determine a position.

A wire is strung over the entire length of the positioning equipment. A strong permanent magnet is situated at a certain position.

A current pulse is sent by wire at regular intervals (i.e. 1k/sec) with several ampere and a length of several microseconds. This high current pulse results in a magnetic field around the wire, which changes rapidly. The position where the magnetic field of the permanent magnet is situated, an energy is generated that winds around the wire and generates an ultrasonic wave, which extends into both directions of the wire (at app. 2,700 m/sec) with ultrasonic speed. In the ?dead" side the ultrasonic impulse is absorbed, whereas the "active" side detects the impulse via ultrasonic receiver, which also converts it into a digital receiver impulse. The time between the start of the pulse and receiving of the receiver impulse is measured via TDC so that the location of the permanent magnet can be determined. In cases where the permanent magnet moves with the positioned parts (i.e. a milling cutter) the equipment can be positioned precisely.

This procedure permits positioning precision of 2-5 µm, which equals an ultrasonic delay time of 800 ps ? 2 ns, which is exactly the range that a TDC has to offer. With a high resolution, which is located slightly above the requirements, TDCs are ideal for time difference measurements. In addition, these chips are extremely small in comparison to past solutions, are ten times as precise while using only 1/10 of the power. All of these features contribute to the increase in distribution of TDCs.