• Precision Measurement Technologies
  • Technology Center for

UFC TDC-GP22 Specifications

Resolution

typ. 90 ps, 45 ps in double resolution mode, 22 ps in quad resolution mode (only Measure Mode 2)

Other Specs

Max data rate:up to 1 million samples per second
Power supply voltage:2.5 V to 3.6 V
Operating temp:-40°C to 125°C
Quiescent current:< 0.1µA
INL:< 0.1 LSB
DNL:< 0.8 LSB

GP22 DC Parameters

GP22 DC Parameters

(click to enlarge)

Time Measuring Unit

Time Measuring Unit

(click to enlarge)

Temperature Measuring Unit

Temperature Measuring Unit

(click to enlarge)